Systems findings

15 findings covering plumbing, electrical and mechanical systems.

Plumbing, electrical and mechanical. Where structure findings are driven by the ground a house sits on, systems findings are driven almost entirely by the decade it was built in.

That makes them more predictable than most buyers expect. A 1968 house in North Texas has a knowable set of candidates: a panel brand that is now controversial, aluminium branch circuits if it was wired late in the decade, cast iron waste lines below the slab. A 1994 house has a different set — polybutylene supply lines, a first-generation post-tension slab, an air handler in an unconditioned attic. A 2006 house has CPVC and a radiant barrier and very little else.

The subject attracts more folklore than any other part of an inspection, and most of it is repeated confidently by people selling the remedy. Federal Pacific breakers were never recalled — the Consumer Product Safety Commission closed its investigation in 1983 on cost grounds, which is a materially different and rather more troubling fact. Twist-on pigtailing does not fix aluminium wiring, though it is sold as if it does. A camera in a sewer line shows condition, not whether the line needs replacing.

Each page below states what an inspector is permitted to determine under the Standards of Practice, what requires a licensed plumber or electrician, and where a widely repeated claim does not survive contact with the source.

FindingVerdictEraWhat it is
Aluminium branch circuit wiringGet it evaluated1960s–1970sWhere the hazard actually is, and which repairs CPSC will accept
Cast iron sewer linesGet it evaluatedPre-1960The expected material under older DFW slabs, and what actually decides its condition
Ductwork and condensate in unconditioned atticsGet it evaluatedEvery eraWhy the equipment above your ceiling is the equipment that damages the house
Federal Pacific Stab-Lok panelsGet it evaluated1960s–1970sThe recall that never happened, and why the truth is worse than the myth
Slab leaksGet it evaluatedEvery eraSupply side against drain side, what actually finds one, and why the water comes before the foundation
Zinsco and Sylvania panelsGet it evaluated1960s–1970sThe evidence here is thinner than for Federal Pacific, and that matters
GFCI and AFCI protectionBudget for itEvery eraWhy your report flags missing protection on a house that was built correctly
HVAC age, sizing and capacityBudget for itEvery eraWhat an inspector measures, and what nobody can honestly tell you about service life
Irrigation systems and backflow preventionBudget for itEvery eraWhy the sprinkler system is a foundation system here, and what the inspection rule leaves out
Polybutylene supply plumbingBudget for it1980s–1990sThe chemistry, the closed class action, and what is actually documented about insurance and lending
Service entrance, grounding and bondingBudget for itEvery eraThe ground rod does not trip your breaker. Bonding does.
Water heaters — TPR valves, pans, expansionBudget for itEvery eraThe safety devices that get defeated, and why attic installations change the stakes
CPVC and PEX supply linesMonitor2000sThe 1990s CPVC decade, the PEX era, and how to read what is printed on the pipe
Sewer scope — what it actually findsMonitorPre-1960What a camera in a drain line can show, what it cannot, and who is interpreting it
Wood-destroying insect inspectionsMonitorEvery eraA separate licence, a separate form, and a report that answers a narrower question than buyers expect