Systems findings
15 findings covering plumbing, electrical and mechanical systems.
Plumbing, electrical and mechanical. Where structure findings are driven by the ground a house sits on, systems findings are driven almost entirely by the decade it was built in.
That makes them more predictable than most buyers expect. A 1968 house in North Texas has a knowable set of candidates: a panel brand that is now controversial, aluminium branch circuits if it was wired late in the decade, cast iron waste lines below the slab. A 1994 house has a different set — polybutylene supply lines, a first-generation post-tension slab, an air handler in an unconditioned attic. A 2006 house has CPVC and a radiant barrier and very little else.
The subject attracts more folklore than any other part of an inspection, and most of it is repeated confidently by people selling the remedy. Federal Pacific breakers were never recalled — the Consumer Product Safety Commission closed its investigation in 1983 on cost grounds, which is a materially different and rather more troubling fact. Twist-on pigtailing does not fix aluminium wiring, though it is sold as if it does. A camera in a sewer line shows condition, not whether the line needs replacing.
Each page below states what an inspector is permitted to determine under the Standards of Practice, what requires a licensed plumber or electrician, and where a widely repeated claim does not survive contact with the source.
| Finding | Verdict | Era | What it is |
|---|---|---|---|
| Aluminium branch circuit wiring | Get it evaluated | 1960s–1970s | Where the hazard actually is, and which repairs CPSC will accept |
| Cast iron sewer lines | Get it evaluated | Pre-1960 | The expected material under older DFW slabs, and what actually decides its condition |
| Ductwork and condensate in unconditioned attics | Get it evaluated | Every era | Why the equipment above your ceiling is the equipment that damages the house |
| Federal Pacific Stab-Lok panels | Get it evaluated | 1960s–1970s | The recall that never happened, and why the truth is worse than the myth |
| Slab leaks | Get it evaluated | Every era | Supply side against drain side, what actually finds one, and why the water comes before the foundation |
| Zinsco and Sylvania panels | Get it evaluated | 1960s–1970s | The evidence here is thinner than for Federal Pacific, and that matters |
| GFCI and AFCI protection | Budget for it | Every era | Why your report flags missing protection on a house that was built correctly |
| HVAC age, sizing and capacity | Budget for it | Every era | What an inspector measures, and what nobody can honestly tell you about service life |
| Irrigation systems and backflow prevention | Budget for it | Every era | Why the sprinkler system is a foundation system here, and what the inspection rule leaves out |
| Polybutylene supply plumbing | Budget for it | 1980s–1990s | The chemistry, the closed class action, and what is actually documented about insurance and lending |
| Service entrance, grounding and bonding | Budget for it | Every era | The ground rod does not trip your breaker. Bonding does. |
| Water heaters — TPR valves, pans, expansion | Budget for it | Every era | The safety devices that get defeated, and why attic installations change the stakes |
| CPVC and PEX supply lines | Monitor | 2000s | The 1990s CPVC decade, the PEX era, and how to read what is printed on the pipe |
| Sewer scope — what it actually finds | Monitor | Pre-1960 | What a camera in a drain line can show, what it cannot, and who is interpreting it |
| Wood-destroying insect inspections | Monitor | Every era | A separate licence, a separate form, and a report that answers a narrower question than buyers expect |
Every era
8 findingsFindings that turn up in North Texas houses of any age.
Pre-1960
2 findingsCast iron waste lines, plank decking, pier and beam, original service equipment.
1960s–1970s
3 findingsThe panel and wiring era — Federal Pacific, Zinsco, aluminium branch circuits.
1980s–1990s
1 findingPost-tension slabs become standard; polybutylene supply lines appear.
2000s
1 findingCPVC and PEX, radiant barriers, tighter envelopes.